Safire 3800A White 12 V Diesel Cabin Heater Package with GSM
Safire 3800A White – Efficient, High-Performance Heater for Off-Grid Holiday Homes
Package includes
GSM remote control unit for Safire heaters
Coaxial flue gas wall outlet kit for wall thicknesses up to 0.4 m:
Touch-safe exhaust pipe
Insulation
Connection box
0.6 m acid-resistant exhaust/air pipe
30-litre fuel tank
Dimensions: 295 × 315 × 475 mm
Product description
The Safire 3800 is the latest model in the Safire range of heaters designed for holiday homes. It sets new standards in heating output adjustment range and user comfort.
Safire heaters have become extremely popular among owners of holiday homes and boats. One of their key features has always been their exceptionally wide heating output range. This allows the thermostat to maintain a comfortable indoor temperature both during the coldest winter months and when only a small amount of heating is required.
In practice, low, automatically controlled heating output is needed far more often than maximum power.
The Safire 3800A offers an even wider output range than previous models, with maximum heating output exceeding four times the minimum output. This is particularly important for maintaining a stable indoor temperature.
For example, if a fireplace is used as an additional heat source, the Safire automatically reduces its output as the room temperature rises, compensating for fluctuations in the heat produced by the fireplace. When the fireplace cools down overnight, the Safire automatically increases its output to maintain a stable temperature.
Unlike previous models, the Safire 3800A is equipped with an additional fan that improves the circulation of heated air. This fan operates only when the heater is running at maximum output. At heating outputs below 3 kW, the additional fan is not used, helping to minimise electricity consumption.
GSM remote control
The Safire heater can be conveniently controlled using GSM text messages. This means your holiday home can already be warm when you arrive.
In power-saving mode, the Safire minimises electricity consumption by checking for incoming messages once every hour. During the rest of the time, the modem is completely switched off. This is a unique Safire feature.
You can also:
Check the indoor temperature remotely.
Check the battery charge level.
Adjust the thermostat setting.
Start and stop the heater.
Request operating status reports.
Receive fault notifications.
The Safire 3800 features a basic control panel integrated into the heater base.
Control panel functions
ON mode
The heater starts and the desired temperature is adjusted using the push button. The unit remembers the last temperature setting used.
AUTO mode
The heater can be controlled remotely using the Safire 1287 control unit via SMS. Functions include starting and stopping the heater, temperature adjustment, status reports, power-saving mode and alarm notifications.
Any operating faults are displayed as error codes on the control panel and can also be sent via GSM messages.
The outer casing of the Safire heater is available in either a light-coloured powder-coated finish or a grey brushed stainless steel finish.
Technical specifications
| Specification | Value |
| Fuel | Diesel |
| Recommended fuel | Neste My Diesel or equivalent high-quality diesel |
| Heating output | 900–3800 W |
| Operating voltage | 12 V or 230 V with power supply |
| Current consumption (900–3000 W) | 0.15–0.35 A (3.6–8.4 Ah/day) |
| Current consumption (900–3800 W) | 0.15–0.80 A (3.6–19.2 Ah/day) |
| GSM power-saving mode | 23 mA (0.55 Ah/day) |
| GSM power-saving mode / basic control | 7 mA (0.17 Ah/day) |
| Temperature and output control | Automatic thermostat control |
| Starting options | Switch, timer or GSM controller |
| Dimensions (H × W × D) | 730 × 310 × 230 mm |
| Weight | 20 kg |
Heating oil can also be used, but it will shorten the recommended service intervals.
Package contents
Heater
3 m fuel hose
Fuel tank connection fitting for the 30-litre tank
4 m power cable
4 m thermostat cable
Additional equipment required
You will also need:
A flue outlet or wall outlet kit.
A 12 V basic solar power system or a suitable battery.
A fuel tank.
Safire Heater Maintenance Guide
Maintenance tips for Safire heaters
Safire heaters are inherently simple and reliable heating appliances. However, like all combustion heaters, they require regular attention and proper maintenance.
The heater uses liquid fuel, so fuel quality and cleanliness are important. Fuel is burned inside the combustion chamber, which must be cleaned periodically to prevent soot accumulation.
Common faults and their causes
Error code 3 – Flame failure
This is the most common error indication. It means that the flame has gone out during the combustion process. The flame may not have been detected at all, or it may have gone out while the heater was running.
Common causes include:
Fuel is not reaching the burner properly.
The burner is sooted up and requires cleaning.
The supply voltage is too low. It may not be low enough to trigger an undervoltage alarm, but still insufficient for reliable ignition.
If the fuel pump does not operate even though the heater attempts to start, the cause may be dirt or contaminated fuel inside the pump.
In such cases, pump cleaning may be necessary. Follow the manufacturer's maintenance instructions or have the pump serviced by a qualified technician.
Important: If error code 3 occurs, do not repeatedly attempt to restart the heater without first identifying and correcting the cause.
Troubleshooting tips
Check that fuel is flowing properly through the fuel hose.
Check the fuel supply line for blockages.
Make sure the battery has sufficient charge and that the correct voltage reaches the heater.
If fuel supply and electrical connections are in order but the heater still fails to start, the burner will most likely require cleaning and servicing.
You can find maintenance instructions in the videos below. We also recommend professional servicing to ensure that the heater is thoroughly inspected and cleaned.
Electrical faults
Another common issue is insufficient electrical power or voltage drop. This is a frequent problem with heating systems.
The battery may appear to have sufficient charge, but a poor electrical connection or voltage drop in the wiring can prevent adequate power from reaching the heater.
Remember:
An undervoltage alarm always indicates an actual supply voltage problem.
The cause is insufficient voltage reaching the heater, usually due to poor connections, undersized wiring or excessive voltage drop.
Error codes and their meanings
Safire error codes are designed to identify specific faults and help diagnose problems quickly. Each code corresponds to a particular operating fault.
| Error code | Description and possible cause |
| 1 – Overheating fault | The heater has overheated. The most common cause is restricted airflow, for example excessively restricted air outlet grilles or too much fuel. Overly closed dampers in the air ducting can also cause this fault. |
| 2 – Ionisation fault | The control board detects a problem with the combustion ionisation sensor electrode. The electrode may be sooted up or faulty. A short circuit between the sensor and heater casing can also cause this error. The sensor can be cleaned according to the maintenance instructions. |
| 3 – Flame detection fault | The heater has shut down because the flame was not detected during combustion. Common causes include an empty fuel tank, a blockage in the fuel system or a burner requiring maintenance. Strong headwinds can also cause this fault if exhaust gases are forced back into the exhaust pipe. |
| 4 – Glow plug fault | The glow plug connector is disconnected, the glow plug is defective, or the connector or wiring is faulty. |
| 5 – Combustion fan fault | A fault in the combustion air fan or its wiring. |
| 6 – Circulation fan fault | A fault in the main circulation fan or its wiring. |
| 7 – Undervoltage fault | The operating voltage is too low. The heater automatically shuts down to prevent damage. |
| 8 – Fuel pump fault | The pump circuit is interrupted or the fuel pump is not receiving power. |
| 9 – Circulation air sensor fault | A fault in the circulation air temperature sensor or its wiring. |
Important!
Safire heaters are extremely reliable when supplied with clean fuel, a stable electrical supply and sufficient airflow.
By following the maintenance recommendations and understanding the error codes, you can ensure long and reliable operation in all conditions.
Safire Maintenance Videos
Watch the videos below for maintenance instructions and practical guidance on servicing Safire heaters.
| Manufacturer | Safire |
| Country of Manufacture | Suomi |
| Color | Valkoinen |
| Käyttökohde | Mökki |
| Jännite | 12V |
| Kayttovoima | Diesel / Polttoöljy |
| Lämmönjakotyyppi | Ilma, vapaa konvektio |
| Minimiteho | 0,9kW |
| Maksimiteho | 3,8kW |
Jos tuote löytyy omasta varastostamme, voit noutaa sen myymälästä tai tilata sen verkkokaupasta.
Jos tuotetta ei ole omassa varastossamme, mutta sitä on saatavilla toimittajalta, verkkokaupassa näkyvä toimitusaika on arvio. Toimittajiemme varastosaldot päivittyvät pääosin automaattisesti päivittäin, mutta saatavuus voi muuttua ennen tilauksen käsittelyä.
Mikäli tuotetta ei ole saatavilla omassa varastossamme eikä toimittajalla, suosittelemme ottamaan yhteyttä asiakaspalveluumme toimitusajan varmistamiseksi ennen tilausta.
Safire
Safire on tunnettu suomalainen vene ja mökkilämmittimien valmistaja.
Tuotekoodi |
3800A-VA-PAKETTI |
Kategoria |
Safire , Seasonal Favourites , Cottage Heaters , Most Popular Heaters , Safire Promotions |
Tags |
Specifications
| Perustiedot | |
|---|---|
| Manufacturer | Safire |
| Country of Manufacture | Suomi |
| Fyysiset | |
|---|---|
| Color | Valkoinen |
| Käyttökohde | Mökki |
| Tekniset | |
|---|---|
| Jännite | 12V |
| Kayttovoima | Diesel / Polttoöljy |
| Lämmönjakotyyppi | Ilma, vapaa konvektio |
| Minimiteho | 0,9kW |
| Maksimiteho | 3,8kW |
| Tags | |
|---|---|
| Tags | |